Under normal circumstances, the speed of the stepper motor back to zero is higher, which will reduce the accuracy of the back to zero. The following describes the setting method of using table control to improve the precision of zero return.
Computer: A computer, as a tool for function setting. Windows 7 is the best system, XP or Windows 10 can also be used.
Controller: one table controlled TPC4-4TD, or other models as required.
Switching power supply: 24V switching power supply.
Data cable: One USB data cable.
Stepper motor: one stepper motor.
First show the wiring method, the wiring of the stepper motor is very simple, the following is a simplified meter control and stepper motor driver wiring schematic, please pay attention to the safety of electricity when wiring:
This page is based on experience
After the fourth line delay of 200 ms, the fifth line is triggered to perform the action of leaving the induction switch X2 at a low speed of 500 Hz, and the rear edge of the X2↑ stops the operation of the stepper motor at the moment of leaving X2. Using this method, each time the zero position will be precisely stopped in the same position, to ensure the accuracy of the stepper motor reference position.
There are many functions of the table control, and to learn more about it, you need to check the instructions, videos, and setup examples.
Ensure that the onsite cables are correctly connected and that the output does not overvoltage or overcurrent. Pay attention to equipment and personal safety during commissioning.